Epoxy composition

ST TOO 180340015806-019-2021

A TWO-COMPONENT POLYAMINE CURED MODIFIED EPOXY COMPOSITION.

Double-packed

Color: grey. Coating: Glossy

Detailed characteristics      Find out the price

Recommended use

It is used as a single coating system for anticorrosive protection of the internal surface of steel tanks, reservoirs, tank cisterns, industrial pipelines.

 

Specifications

In the case of two-layer coating, it provides long-term protection in environments with high corrosive activity: in crude oil, bottom and sea water; chemical solutions with weak acid medium (pH 5-7) and weakly alkaline (pH 8-11) media, washing fluids.

 

In single-layer application, it protects the steel when it comes in contact with commercial oil, liquefied natural gas, lube oils and lubricants, lubricating fluids.

 

The coating is highly abrasion resistant. Recommended operating temperature in liquid fluids is up  to plus 60 °С (for a short time it is allowed up to plus 75 °С, it can stand steaming operation).

 

AREAS OF APPLICATION

The composition ISOLEP-oil 250 is designed specifically for anticorrosive protection of oil and gas facilities.

 

CERTIFICATION

Certificate of State registration No. KG.11.01.09.008.E.005730.09.22 dated 30.09.2022

 

TECHNICAL SPECIFICATIONS

Coating        

Color  grey, pink

Gloss  glossy

Dry film thickness, microns           125 - 200

Composition

Density, g/cm3         1,40-1,55

Pot life at a temperature of (20 ± 2) ° C, h         1, not less

Drying time, h          

- to the degree of 1 (GOST 19007) at a temperature of (23 ± 2) ° C            4.0

- to the degree of 3 (GOST 19007) at a temperature of (23 ± 2) ° C            8.0

Wet firlm thickness, microns         170 - 270

Theoretical consumption per single-layer coating, g/m2         250 – 400

Proportion of non-volatile substances:

- average volume, % vol.

by mass, % (mass)  75

83 - 87

SURFACE PREPARATION

degrease metal surface to the first degree according to GOST 9.402;

Perform abrasive blasting to grade not less than 2 according to GOST 9.402 or Sa 2 ½ according to ISO 8501-1. Surface profile is sharp, angular with a roughness of 85-115 microns

(3G segment according to ISO 8503-2);

remove dust.

The material should be applied no later than 6 hours after abrasive blasting. If it is necessary to apply a second layer of material, the application surface must be clean from dirt, degreased, dust-free and dry.

 

INSTRUCTIONS FOR USE

Mix the base to a homogeneous condition before application; with constant stirring, add the hardener to the base, mix thoroughly for 2-3 minutes to a homogeneous condition.

The proportion of base and hardener: by mass 6.2:1, by volume 4:1.

 

The pot life (after mixing the components) at ambient temperature (20±2)°C is not less than 1 hour.  For the organization of painting, the decrease of the pot life with increasing temperature should be taken into account.

 

The material may be applied at an ambient temperature of 0 to plus 40 °C and relative humidity not more than 80 %.

 

The temperature of painted surface should be at least 3 °C above the dew point, but not above plus 40 ° C.

 

When painting, the temperature of the material must be not less than plus 15 °C.

 

It is recommended to use both single-layer and two-layer coating depending on the operating environment (please refer to "Recommended use" or further clarify from the manufacturer).

 

Recommended application parameters:

 

 Airless spraying

 

 Recommended diluent      SOLV-EP (ST TOO 180340015806-028-2021)

 Amount of diluent   not more than 5% by mass

 Pressure      20 - 30 MPa (200 - 300 bar)

 Nozzle diameter      0.015" - 0.021" (0.38 - 0.53 mm)

 Air spraying

 Recommended diluent      SOLV-EP

 Amount of diluent   not more than 5% by mass

 Brush / Roller

 

 Recommended diluent      SOLV-EP

 Amount of solvent  not more than 5% by mass

 Equipment cleaning

 SOLV-EP, thinners 646, 647, 649

Drying of coating is natural. As the temperature increases, the drying time decreases.

 

The minimum and maximum exposure time of ISOLEP-oil 250 coating before the next layer application (if necessary), as well as the time for its full hardening (start time for use) are given in the table (for a dry film thickness of 150 microns).

 

Drying degree

Time, h (hours), day (day)

at ambient temperature, °C      

 

0          5          10        15      20      25      30      40

 Tack dry       29 hrs.            22 hrs.           15 hrs.            9 hrs.  4,5 hrs.          3,5 hrs.          2,5 hrs.            1 hrs.

 Minimum time

 before applying the next layer     38 hrs.           30 hrs.            20 hrs.           13 hrs.            8 hrs.  5 hrs.            3,5 hrs.          2,5 hrs.

 Maximum time

 before applying the next layer     13 days          10 days

7 days            5 days            4 days            4 days            3 days            2 days

 Full cure       27 days          20 days          15 days

10 days          7 days            6 days            4 days            2 days

The specified curing time is recommended to be taken as an indicative for practical painting. The curing time depends on the surface temperature and ambient air, the degree of dilution of the material, coating thickness, ventilation efficiency and relative humidity.

 

If the maximum overlap time is exceeded, it is necessary to carry out an additional surface treatment for roughening (light sweeping).

 

STORAGE AND HANDLING

The material is supplied as a complete set: base and hardener, packed in metal buckets and metal cans.

 

Storage conditions is in accordance with GOST 9980.5 (at ambient temperatures from minus 40 to plus 40 °С). The material components shall be stored away from heat sources, the container shall be protected  from direct sunlight (short-term - not more than 3 hours is allowed) and atmospheric condensation.

 

The shelf life of the components is 24 months starting with the date of manufacture.

SECURITY MEASURES

When working, comply with the relevant industry standards and requirements, as well as the precautions indicated on the container label. Use personal protective equipment (glasses, masks, respirators), avoid inhalation of thinners during evaporation and contact of the composition or its components with the skin, mucous membranes of the eyes and respiratory tract; use indoors only if sufficient ventilation is provided.

 

The composition and its components (base and hardener) are flammable! The hardened coating is not harmful to human health.

 

COMPATIBILITY OF THE ISOLEP-oil 250 COMPOSITION WITH OTHER VMP MATERIALS

The composition of ISOLEP- oil 250 is used as a single coating system.

 

Information provided is general in nature and does not take into account the specifics of a particular object.

Compatible materials:

 

SOLV-EP



For qualified assistance in selecting the optimal protective coating system, please contact LLP "VMP ASTANA PLANT": +7 (7172) 69-53-74.
Also, for the convenience of users, the site operates an  On-line request.