Яндекс.Метрика

ISOLEP®-epoline

ISOLEP®-epoline
Epoxyurethane composition

ISOLEP-epoline

TU 20.30.12-018-67503963-2019

EPOXYURETHANE COMPOSITION

Double-packed

Color: white, gray, red-brown, black, and others. Gloss value: Glossy

Detailed characteristics      Find out the price

Recommended use

ISOLEP-epoline is a double-packed epoxy polyurethane composition. It is designed to form a functional coating with high chemical resistance and protective properties. This composition is used to protect metal, reinforced concrete and other mineral surfaces of structures operated in an industrial atmosphere (in the absence of UV radiation) and exposed to aggressive media: gases, aqueous solutions of salts, short-term dousing with acids, alkalis, oil and petroleum products, as well as mechanical wear and abrasion.

Specifications

Primer-enamel ISOLEP-epoline

 

An epoxyurethane composition with an isocyanate-type curing agent and a high solids content.

Coating

 

The coating is chemically resistant to aggressive atmospheric factors, to UV radiation; resistant to mechanical effect and abrasion.

AREAS OF APPLICATION

ISOLEP-epoline is used to protect metal, reinforced concrete and other mineral surfaces of structures.

 

CERTIFICATION

Certificate of state registration No. RU.77.01.34.008.E.003241.12.21 dated 20.12.2021

 

TECHNICAL SPECIFICATIONS

 Density of primer- enamel, g/cm3           1,75 ±0,10

 Pot life at a temperature of (20 ± 2) ° C, h

 min.

 40

  Proportion of non-volatile substances:

by volume, % vol.

by mass, % (mass.)

 

 

 90±2

 95, not less than

 Dry film thickness, microns           50-150

 Wet film thickness of one layer, microns           55-170

 Drying time at a temperature of (20 ± 0.5) ° C

  to 3 degree (GOST 19007), hrs., no more than           

18

CONSUMPTION PER M2

The theoretical consumption for a single-layer coating is 100-300 g/m2.

 

SURFACE PREPARATION

Metal surface:

degrease metal surface to the first degree according to GOST 9.402;

clean from scale, rust and old paint by abrasive blasting up to the degree of Sa 2½ according to ISO 8501-1 (degree 2 according to GOST 9.402), it is allowed to clean by mechanized and manual tools up to the degree of St 3 according to ISO 8501-1 (degree 3 according to GOST 9.402);

remove dust.

Concrete:

remove dirt, oil and grease contamination;

remove lime milk or laitance, destroyed or flaking concrete layers and old coatings by abrasive  cleaning, grinding machine or brushes;

dedusting;

repair cracks and chips.

The exposure of the concrete base after removing the formwork before applying the composition should be at least 28 days; after applying leveling mixtures – according to the regulatory documentation of  the mixture manufacturer. The moisture content of the base should not exceed 4 %

The concrete surface prepared in accordance with SNiP 3.04.03-85 for applying the paintwork should be evenly rough and not have protruding reinforcement, cracks, potholes, sinks, sagging, chipping ribs, oil stains, dirt and dust.

Before applying the second layer, the coating must be dry, clean and free of oil and dust.

 

INSTRUCTIONS FOR USE

prior to use, mix the base thoroughly until smooth;

with constant stirring, add the hardener to the base and mix thoroughly;

if necessary, dilute to working viscosity.

The material is recommended to be applied at a temperature of plus 5 to plus 35 ° C and a relative humidity of no more than 80%. Temperature of the painted surface must be at least 3 °C above the dew point.

To increase the viability of the composition up to 1 hour, dilution with SOLVIN-15 thinner (TU 20.30.22-014-67503963-2018) in an amount of 5-10 % by weight is recommended.

The composition is recommended to be applied in 1-2 layers by airless, pneumatic spraying, brush / roller.

Application methods:

 

 Airless spraying

 

 Recommended diluent      without dilution

 Pressure      15-22 MPa (150-220 bar)

 Nozzle diameter      0.015’-0.021’ (0.38-0.53 mm)

 Air spraying

    

 Recommended diluent      SOLVIN-15

 Amount of diluent   up to 10% by mass

 Pressure      0.2-0.4 MPa (2-4 bar)

 Nozzle diameter      1.8-2.2 mm

 Brush / Roller

 

 Recommended diluent      SOLVIN-15

 Amount of diluent   up to 10% by mass

 Equipment cleaning

 SOLVIN-15, solvents P-4, toluene, xylene

Intermediate drying between layers of the composition at a temperature of plus 20 ° C – at least 16 hours. The curing time depends on the surface temperature and ambient air, the degree of dilution of the material, coating thickness, ventilation efficiency and relative humidity.

The exposure time of the coating before use in aggressive conditions is at least 7 days at a temperature of (20 ± 2) ° C.

 

STORAGE OF ANTICORROSIVE PRIMER ENAMEL

The material is supplied as a complete set: the base and hardener are packaged in metal buckets and metal cans, respectively, depending on the weight of the kit.

 

Storage conditions is in accordance with GOST 9980.5 (at ambient temperatures from minus 40 to plus 40 °С). When storing containers with material components, they should not be placed near heat sources, exposed to atmospheric condensation and direct sunlight.

 

The shelf life is determined by the warranty periods of storage of the base and hardener of the composition – 12 months from the date of manufacture.

 

SECURITY MEASURES

When working, comply with the relevant industry standards and requirements, as well as the precautions indicated on the container label.

 

Use personal protective equipment (glasses, masks, respirators), avoid inhalation of solvents during evaporation and contact of the material or its components with the skin, mucous membranes of the eyes and respiratory tract; use indoors only if sufficient ventilation is provided.

 

The material and its components (base and hardener) are flammable!

For qualified assistance in selecting the optimal protective coating system, please contact LLP "VMP ASTANA PLANT": +7 (7172) 69-53-74.
Also, for the convenience of users, the site operates an  On-line request.